This creates opportunities for new trials that incorporate SABR a

This creates opportunities for new trials that incorporate SABR and patient-specific systemic strategies. This selective mini-review focuses on the emerging role of SABR in patients with early-stage and oligometastatic NSCLC.”
“Scale up studies for production of lipoic acid (LA) from Saccharomyces cerevisiae have been reported in this paper for the first time. LA production in batch mode was carried out in a stirred tank bioreactor at varying agitation and aeration with maximum LA production of 512 mg/L obtained at 350 rpm and 25 % dissolved oxygen in batch culture conditions. Thus, LA production increased from 352 mg/L in shake flask to 512 mg/L in batch mode

in a 5 L stirred tank bioreactor. Biomass production under these conditions was mathematically explained using logistic equation and data obtained for LA production and substrate utilization were see more successfully fitted using Luedeking-Piret and Mercier’s models. The kinetic studies showed LA production to be growth associated. Further enhancement of LA production was carried out using fed-batch (variable volume) and semi-continuous modes of fermentation. Semi-continuous fermentation with three feeding cycles of

sucrose selleck chemical effectively increased the production of LA from 512 to 725 mg/L.”
“Background Surgery is the fundamental curative option for gastric cancer patients. Imaging scans are routinely prescribed in an attempt to stage the disease prior to surgery. Consequently, the correlation between radiology exams and pathology is crucial for appropriate treatment planning.

Methods Systematic searches were conducted click here using Medline, Embase, and the Cochrane Central Register of Controlled Trials from January 1, 1998 to December 1, 2009. We calculated the accuracy, overstaging rate, understaging rate, Kappa statistic, sensitivity, and specificity for abdominal ultrasound (AUS), computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography

(PET) with respect to the gold standard (pathology). We also compared the performance of CT by detector number and image type. A meta-analysis was performed.

Results For pre-operative T staging MRI scans had better performance accuracy than CT and AUS; CT scanners using >= 4 detectors and multi-planar reformatted (MPR) images had higher staging performances than scanners with <4 detectors and axial images only. For pre-operative N staging PET had the lowest sensitivity, but the highest specificity among modalities; CT performance did not significantly differ by detector number or addition of MPR images. For pre-operative M staging performance did not significantly differ by modality, detector number, or MPR images.

Conclusions The agreement between pre-operative TNM staging by imaging scans and post-operative staging by pathology is not perfect and may affect treatment decisions.

Comments are closed.